Keyboard shortcuts

Press ← or → to navigate between chapters

Press S or / to search in the book

Press ? to show this help

Press Esc to hide this help

EHDS readiness

The European Health Data Space regulation, Regulation (EU) 2025/327 (https://eur-lex.europa.eu/eli/reg/2025/327/oj), names six priority categories of personal electronic health data in Article 14(1). It requires them in the European electronic health record exchange format (Article 15), whose technical specifications the Commission lays down by implementing act. That implementing act has not been adopted. No profile version is legally pinned, and nothing on this page is a conformance claim.

The HL7 Europe implementation guides are the current proxy for the exchange format, and FerroBRIDGE targets them on FHIR R4. When the implementing act is adopted, the targets below are re-read against it.

This page is the FHIR facade’s mapping matrix. The European interoperability software component an EHR system carries under Art 25(1), with its dataset model, its category crosswalks and the receipt of a document, is the eehrxf crate (The interoperability component).

The matrix

Each row is a target profile with the committed template it maps from and the round-trip test that proves the transform. A test generates the matrix from docs/ehds/readiness.toml and fails when a template, a context or a test it names is gone. “Produced, not claimed” means the resource is built but does not name the profile in meta.profile. A gap means the openEHR international CKM publishes no template for the category.

Article 14(1)(a): Patient summaries

HL7 Europe Patient Summary 1.0.0-ballot is pinned for the profile validator; no context maps its Composition yet. The Base and Core profiles below are its building blocks.

Target profilePackageCommitted templateTransform proven
patient-eu-corehl7.fhir.eu.base 2.0.0KDS_Personthe_profile_elements_of_patient_eu_core_survive_the_round_trip
condition-eu-corehl7.fhir.eu.base 2.0.0KDS_Diagnosethe_profile_elements_of_condition_eu_core_survive_the_round_trip
medicalTestResult-eu-corehl7.fhir.eu.base 2.0.0KDS_Laborberichtthe_profile_elements_of_the_test_result_survive_the_round_trip
Patient summary Compositionhl7.fhir.eu.eps 1.0.0-ballotnone: no patient summary template in the openEHR international CKMno

Article 14(1)(b): Electronic prescriptions

Target profilePackageCommitted templateTransform proven
MedicationRequest-eu-mpdhl7.fhir.eu.mpd 1.0.0FerroBRIDGE medication template over CKM archetypesthe_profile_elements_of_the_prescription_survive_the_round_trip
Medication-eu-mpdhl7.fhir.eu.mpd 1.0.0FerroBRIDGE medication template over CKM archetypesthe_product_of_the_prescription_survives_the_round_trip
Dosage-eu-mpd (produced, not claimed)hl7.fhir.eu.mpd 1.0.0FerroBRIDGE medication template over CKM archetypesthe_dosage_of_the_prescription_survives_the_round_trip

Article 14(1)(c): Electronic dispensations

The openEHR international CKM publishes no dispensation template; the template is FerroBRIDGE’s, over published CKM archetypes only (owner ruling on #116).

Target profilePackageCommitted templateTransform proven
MedicationDispense-eu-mpdhl7.fhir.eu.mpd 1.0.0FerroBRIDGE medication template over CKM archetypesthe_profile_elements_of_the_dispense_survive_the_round_trip

Article 14(1)(d): Medical imaging studies and related reports

HL7 Europe Imaging Report is at 1.0.0-ballot and deferred (docs/architecture.md section 4.8).

Target profilePackageCommitted templateTransform proven
Imaging report Compositionhl7.fhir.eu.imaging 1.0.0-ballotnone: no imaging report template in the openEHR international CKMno

Article 14(1)(e): Medical test results, laboratory results and related reports

Target profilePackageCommitted templateTransform proven
DiagnosticReport-eu-labhl7.fhir.eu.laboratory 2.0.0KDS_Laborberichtthe_profile_elements_of_the_laboratory_report_survive_the_round_trip
Observation-resultslab-eu-labhl7.fhir.eu.laboratory 2.0.0KDS_Laborberichtthe_profile_elements_of_the_laboratory_result_survive_the_round_trip
Specimen-eu-labhl7.fhir.eu.laboratory 2.0.0KDS_Laborberichtthe_profile_elements_of_the_laboratory_specimen_survive_the_round_trip
Composition-eu-labhl7.fhir.eu.laboratory 2.0.0KDS_Laborberichtthe_profile_elements_of_the_document_composition_survive_the_round_trip
Bundle-eu-lab (produced, not claimed); assembled by the facade’s Composition/$document, proven on a synthetic Composition context; the claimed document is the interoperability component’s (eehrxf) laboratory documenthl7.fhir.eu.laboratory 2.0.0KDS_Laborberichtthe_document_is_the_composition_and_every_resource_it_creates

Article 14(1)(f): Discharge reports

HL7 Europe Hospital Discharge Report 1.0.0 (R4, 2026-10-16) is pinned, and the interoperability component (eehrxf) holds its crosswalk; no context maps its Composition, because no template carries a discharge report.

Target profilePackageCommitted templateTransform proven
Discharge report Compositionhl7.fhir.eu.hdr 1.0.0none: no discharge report template in the openEHR international CKMno